Showing results: 106 - 120 of 255 items found.
-
518 -
Sensoray Co., Inc
Measures thermocouples, RTDs, strain gages, thermistors, 4-20 mA, voltage and resistance 8 high-accuracy differential input channels Integral sensor excitation Exclusive pulsed excitation minimizes sensor self-heating Configurable sensor type per channel Fully electronic calibration Low power
-
E9320 Series -
Keysight Technologies
- Operates with the EPM-P series and P-Series power meters- 300 kHz, 1.5 MHz and 5 MHz video (modulation) bandwidths- Provides peak and average power measurements- Calibration factors stored in EEPROM- Fast measurement speed over the GPIB (up to 1,000 readings per second)- Two frequency ranges: 50 MHz to 6 GHz, and 50 MHz to 18 GHz- Wide dynamic range sensors
-
CDN -
EMCTEST
The CDN M5 is intended to inject common mode disturbance signals to power supply of mains lines (unscreened) in the frequency range from 150KHz to 230MHz. A variety of calibration adapters and other accessories are available as an option. RF Standard connector: BNC type, AC socket 4mm safety bananas.
-
DCS025 -
Teledyne LeCroy
The DCS025 Deskew Calibration Source generates time-aligned voltage and current pulses for precise deskew of voltage and current probes.This is critical for measurements in which small propagation delay differences between probes can have a large impact on a calculated measurement, e.g., instantaneous power semiconductor device loss measurements.
-
2406B -
Chitai Electronic Corporation
‧Simultaneous display of W, A, V (PF or Hz)‧True RMS V, A, W‧Auto calibration via computer‧Data Hold∕Range Hold function‧Hight immunity to external noise‧CT ratio (1~99)‧REF function (0.800 ~ 1.200)‧Aux. power is AC 90 ~ 260V, 50/60Hz‧RS-232 interface (option)
-
General Purpose -
Encore Electronics, Inc.
Encore offers a complete line of General Purpose Signal Conditioning instrumentation to meet even the most demanding requirements. Packaged as interchangeable two-channel plug-in modules, Encore’s broad product line includes frequency to voltage converters, strain gage amplifiers, accelerometer conditioners, digital voltmeters and DC power supplies. All of our systems feature a common CAL input on the rear of the rack which allows for calibration of the entire rack. Calibration function varies based on the modules installed. For example, the Model 633 applies a shunt calibration resistor across the bridge, while the Model 149 applies a reference charge source to the input. Contact Encore today and let our team of design engineers help you determine which of our products is best for your application.
-
MODEL TMO-2 -
Transducer Techniques, Inc
The TMO-2 Transducer Modules is a complete differential amplifier/signal conditioners with self contained power. The units provide excitation, balance and span adjustment via precision 10 turn pots, and shunt calibration necessary to couple a user supplied bridge type transducer to an indicating instrument. Full scale output is specified at plus or minus 10 VDC. The TMO-2 provides a floating shunt calibration circuit which applies calibration at the transducer, thereby eliminating errors due to line losses. The excitation supply incorporates a Wagner Ground to greatly improve Common Mode Rejection. The factory set bandwidth of the module is narrow to improve stability for applications such as weighing scales. The removal of a single capacitor will increase the frequency response DC to 60K Hz for dynamic data applications.
-
Dr. Brockhaus Messtechnik GmbH & Co. KG
Electromagnet systems with different power levels to produce homogeneous magnetic fields. Usable for calibration of sensors, testing of magnet systems and Hysteresis measurement. Adjustable air gap from 0 up to 60 mm. Field strength in the air gap up to 3 Tesla. Software program for control and evaluation.
-
NI-RFmx Noise Figure -
NI
Measure noise figure, gain, Y-factor, effective temperatures, hot and cold power, and moreOptimized calibration and measurement routines for multi-DUT test using Y-factor and cold sourceSupports the PXIe-5668R 26.5 GHz VSA, the PXIe-5698 26.5 GHz preamplifier, and VSTsDesigned for use with industry-standard noise sources such as the Noisecom NC346 Series
-
LRB1000/LRB2000 -
Electro-Sensors, Inc.
Features• Works with remote/external pulse frequency output sensor (NPN, PNP)• Over- or under-speed 1-1,000 rpm• 1 SPDT relay output (LRB1000) or 2 SPDT relay outputs (LRB2000)• Visual setpoint adjustment with digital accuracy• Dial-in calibration does not require power• Built-in start delay• DIN rail mounting simplifies installation• 115, 230 VAC (50-60 Hz) and 12, 24 VDC power options
-
E9301A -
Keysight Technologies
Measure the average power of all modulation formats Wide dynamic range (-60 dBm to +20 dBm) and frequency range 10 MHz to 6 GHzHigh maximum power specification Low SWR for reducing mismatch uncertainty Calibration factors linearity and temperative compensation data stored in EEPROM Fast measurement speeds (up to 400 readings per second with the Keysight E4416A)Compatible with EPM (new N1913A/ 14A, E4418B/ 19B), EPM-P (E4416A/ 17A) and P-series (N1911A/ 12A) power meters
-
IMADA, Incorporated
Automatic Breakaway Torque Tester can be used to verify the actual tightened torque of a bolt. Torque controlled power tools are set to apply consistent torque, but fasteners are not necessarily tightened to that value if the tools are out of calibration. Breakaway torque tests require a skilled, experienced operator to sense when the bolt begins to breakaway.
-
TorqueLab® LTT-Series -
Mountz Inc.
The torque analyzer is designed for calibrating tools, joint testing, auditing and measuring torque. Torque tools go out of calibration with use. To maintain consistent accuracy, torque tools must be checked periodically for wear or defective parts. A power or hand torque tool is a measuring tool that must be properly calibrated and maintained.
-
Iconic Engineering Limited
As a service provider, we have a wide range of provisions in industrial services. We provide industrial testing, service, power quality monitoring, Calibration Service, Thunder protection System,s and so on. Our service includes high precision instruments which give more reliable data than any service.
-
Precision Milimeter Wave
Standard gain horns can be used to experimentally determine the gain of other antennas by using the substitution method. The standard gain horn and the antenna under test are alternately connected to a well matched detector system in order to compare their relative power levels. The power level difference is then added to the appropriate level of the calibration curve to determine the absolute gain of the antenna under test.View more Standard Gain Horn Antennas